Injection Grout

Unintended voiding was detected through non-destructive testing between wythes of what were supposed to be solidly bonded, historic multi-wythe brick walls.

The cavities were plunge drilled, jet-cleaned, steam-damped and then injected with VoidSpan PHLc70 grout in order to properly solidify the walls.